Empty batt. behaviour – instant motor cut-off | Yes |
---|---|
Setting of the range of neutral zone | Yes |
Possibility of switching reversible controller into “one-way” mode | Yes |
Reversible controller (both-way mode) | Yes |
Bidirectional “both-way” mode | Yes |
ACL – Automatic Current Limiting | Yes |
ACR – Automatic Current Reduce | Yes |
Temperature fuse of the controller | Yes |
Current fuse of the controller | Yes |
False-start protection | Yes |
Masking of interference | Yes |
Software reversal of rotation | Yes |
Empty batt. behaviour – motor power reduction | Yes |
Adjustable deceleration speed | Yes |
Adjustable acceleration speed | Yes |
External signalization of important states | Yes |
Possibility of connecting plane position lights and flashing lights | Yes |
Active free-wheeling circuit ON / OFF | Yes |
Possibility of automatic setting of throttle limits | Yes |
Possibility of manually set timing | Yes |
Automatically set timing | Yes |
Manually set type of cells | Yes |
Possibility of manually set number of cells | Yes |
Possibility of automatic setting of cut off voltage | Yes |
Possibility of setting switching off voltage | Yes |
Possibility of setting an amount of residual energy for BEC | Yes |
Possibility of setting the voltage of BEC | Yes |
Possibility of very powerful switching BECs | Yes |
Possibility of setting current limits | Yes |
Possibility of setting RPM limits | Yes |
Possibility of motor temperature measuring | Yes |
Possibility of cells temperature measuring | Yes |
Outstanding cells management | Yes |
Very high resistance against overloading | Yes |
Plug and Play (functional immediately without the need for additional programming) | Yes |
ICS-2 connector – super-fast PC connection link | Yes |
Programming using PC | Yes |
Reading-out of data from the controller using PC | Yes |
Software updates available through internet | Yes |
Telemetry (back data transfer) | Yes |
Real-time Monitoring (PC or other device) | No |
Internal Data Logger (data recorder) | Yes |
Possibility of design with ON/OFF switch (connected safely) | Yes |
Possibility of WR version (full protection against water) | Yes |
Possibility of WP version (increased protection against water) | Yes |
Possibility of design with external heatsinks + FAN | Yes |
Possibility of design with water-cooled heatsinks | Yes |
Possibility of design with external heatsinks | Yes |
Length of the servocable | 190 [ mm ] |
Servocable cross-section | 0.25 [ mm2 ] |
Length of the power conductors | 120 [ mm ] |
Power conductors cross-section to batt. / to mot. | 4/4 [ mm2 ] |
Weight incl. all conductors | 61 [ gram ] |
Weight without power conductors | 36 [ gram ] |
Dimensions with external capacitor | 65×31×17 [ mm ] |
Dimensions | 50×31×17 [ mm ] |
Max RPMs | 250.000 |
On-state switch (FETs) resistance at 25 °C | 2 × 0.4 [ mW ] |
Motor PWM frequency | 8 – 32 [ kHz ] |
Number of regulation steps | 2048 |
BEC short circuit protection | Yes |
Max. BEC current at 25 °C | 6 [ A ] |
Switching HV-BEC voltage | 5 / 6 / 7 / 8 [ V ] |
Switching S-BEC voltage | 5 / 6 [ V ] |
Available BEC / OPTO versions | S-BEC / HV-BEC / OPTO |
Max. peak current (peak 5 sec.) | 150 [ A ] |
Max. continuous current (for full throttle) | 120 [ A ] |
Operating voltage | 6 – 26 [ V ] |
Compatible with all types of feeding cells | Yes |
Number of A123 feeding cells | 3 – 7 |
Number of NiCd, NiMh feeding cells | 6 – 18 |
Number of Li-Pol, Li-Ion feeding cells | 2 – 6 |
“One-way” mode | Yes |
Possibility of setting current limits | Yes |
Possibility of setting RPM limits (motor protection) | Yes |
Possibility of motor temperature measuring (motor protection) | Yes |
Possibility of cells temperature measuring (cells protection) | Yes |
4 Memory Banks | Yes |
32-BIT SYSTEM | Yes |
Automatic Sensor Setting | Yes |
Possibility of operation also with sensors motors | Yes |
Real-time Monitoring (PC or other device) | No |
Telemetry (real-time back data transfer) | Yes |
Internal Data Logger (data recorder) | Yes |